Zemic HM9B load cell are available in the capacities 10t to 50t, alloy steel construction, nickel plated, hermetically welded, oil-proof, waterproof and anti-corrosive gas and medium making it suitable for all kinds of environments. Dual shear beam, suitable for electronic truck scales, railway scales and other electronic weighing devices. It is safety and anti-explosion product that can be used in atrocious weather and hazardous areas.
FEATURES : ZEMIC HM9B LOAD CELL | |
Capacity : 10t t0 50t | High accuracy |
Alloy steel construction | Easy installation, reliable performance |
With OIML approval |
SPECIFICATIONS : ZEMIC HM9B LOAD CELL | ||||||
Capacity | t | 10/20/25/30/40SE/40/50 | ||||
Accuracy | C1 | C2 | C3 | A5M | B10M | |
Approvals | OIML R60 C3 | |||||
Maximum number of verification intervals | n max | 1000 | 2000 | 3000 | 5000 | 10000 |
Minimum load cell verification interval | v min | Emax/3000 | Emax/5000 | Emax/7500 | Emax /15000 | Emax /10000 |
Combined error | %FS | ≤±0.050 | ≤±0.030 | ≤±0.020 | ≤±0.026 | ≤±0.050 |
Creep | %FS/30min | ≤±0.038 | ≤±0.024 | ≤±0.016 | ≤±0.017 | ≤±0.040 |
Temperature effect on sensitivity | %FS/10℃ | ≤±0.028 | ≤±0.017 | ≤±0.011 | ≤±0.013 | ≤±0.040 |
Temperature effect on zero | %FS/10℃ | ≤±0.047 | ≤±0.023 | ≤±0.015 | ≤±0.014 | ≤±0.020 |
Output sensitivity | mV/V | 2.0±0.002 | 2.3±0.002 | 2.4±0.002 | 1.9±0.002 | 1.8±0.002 |
Input resistance | Ω | 700 ±7 | 775 ±5 | 750 ±7 | ||
Output resistance | Ω | 700 ±7 | ||||
Insulation resistance | MΩ | ≥ 5000 (50V DC) | ||||
Zero balance | %FS | 1.5 | ||||
Temperature, compensated | ℃ | -10 ~ +40 | ||||
Temperature, allowed | ℃ | -35 ~ +65 | ||||
Excitation, recommended | V | 5 ~ 12 (DC) | ||||
Excitation, max | V | 18 (DC) | ||||
Safe overload | %FS | 150 | ||||
Ultimate overload | %FS | 300 |