Zemic HM9A load cell are available in the capacities 10t to 50t, alloy steel construction, nickel plated, hermetically welded, oil-proof, waterproof and anti-corrosive gas and medium making it suitable for all kinds of environments. Dual shear beam, suitable for electronic truck scales, railway scales and other elctronic weighing devices.
SPECIFICATIONS : ZEMIC HM9A LOAD CELL | ||||||
Capacity | t | 10/15/20/25/30/40/40SE/50 | ||||
Accuracy | C1 | C2 | C3 | A5M | B10M | |
Max number of verification intervals | n max | 1000 | 2000 | 3000 | 5000 | 10000 |
Mini number of verification intervals | v min | Emax/3000 | Emax/5000 | Emax /10000 | Emax /15000 | Emax /10000 |
Combined error | %FS | ≤ ±0.050 | ≤ ±0.030 | ≤ ±0.020 | ≤ ±0.026 | ≤ ±0.050 |
Creep | %FS/30min | ≤ ±0.038 | ≤ ±0.024 | ≤ ±0.016 | ≤ ±0.017 | ≤ ±0.040 |
Temperature effect on sensitivity | %FS/10℃ | ≤ ±0.028 | ≤ ±0.017 | ≤ ±0.011 | ≤ ±0.013 | ≤ ±0.040 |
Temperature effect on zero | %FS/10℃ | ≤ ±0.047 | ≤ ±0.023 | ≤ ±0.015 | ≤ ±0.014 | ≤ ±0.020 |
Output sensitivity | mV/V | 2.0 ± 0.002 | ||||
Input resistance | Ω | 700 ± 3.5 | ||||
Output resistance | Ω | 703 ± 3.5 | ||||
Insulation resistance | MΩ | ≥ 5000 (50VDC) | ||||
Zero balance | %FS | 1.5 | ||||
Temperature, compensated | ℃ | -10 ~ +40 | ||||
Temperature, allowed | ℃ | -35 ~ +65 | ||||
Excitation, Recommended | V | 5 ~ 12 (DC) | ||||
Excitation, max | V | 18 (DC) | ||||
Safe overload | %FS | 150 | ||||
Ultimate overload | %FS | 300 |
FEATURES | ACCESSORIES |
Capacity : 10t – 50t | Button |
High accuracy | Steel ball |
Alloy steel construction | Ball cup |
Easy installation, reliable performance | Base plate |