SPECIFICATIONS : ZEMIC BM11 LOAD CELL
|
Accuracy class |
OIML R60 C3 |
Output sensitivity (=FS) |
mV/V |
2.0 ± 0.2 |
Maximum capacity (Emax) |
kg |
10, 20, 30, 50, 100 |
200, 300, 500 |
Maximum number of load cell intervals (Nlc) |
|
3000 |
Ratio of minimum LC verification interval Y = Emax / Vmin |
|
10000 – 15000 |
6000 |
Combined error |
%FS |
± 0.020 |
Minimum dead load |
kg |
0 |
Safe overload |
of Emax |
150% |
Ultimate overload |
of Emax |
300% |
Zero balance |
of FS |
< ± 1.0% |
Excitation, recommended voltage |
V |
5 ~ 12 |
Excitation maximum |
V |
18 |
Terminal resistance, input |
Ω |
430 ± 50 |
Terminal resistance, output |
Ω |
351 ± 2 |
Insulation impedance |
MΩ |
5000 (at 50V DC) |
Temperature range, compensated |
°C |
-10 ~ 40 |
Temperature range, operating |
°C |
-35 ~ +65 |
Element material |
|
Stainless steel |
Ingress protection (according to EN 60529) |
|
IP68 |
Recommended torque on fixation bolts |
Nm |
M8 (20-50kg):15 |
M8 (<300kg):25 |
M10:40 |
ATEX classification (optional) |
|
II1G Ex ia II1C T4 |
II1D Ex ia D 20 T73°C |
II3G nL IICT4 |